Goto Section: 76.610 | 76.612 | Table of Contents
FCC 76.611
Revised as of October 1, 2020
Goto Year:2019 |
2021
§ 76.611 Cable television basic signal leakage performance criteria.
(a) No cable television system shall commence or provide service in the
frequency bands 108-137 and 225-400 MHz unless such systems is in
compliance with one of the following cable television basic signal
leakage performance criteria:
(1) Prior to carriage of signals in the aeronautical radio bands and at
least once each calendar year, with no more than 12 months between
successive tests thereafter, based on a sampling of at least 75% of the
cable strand, and including any portion of the cable system which are
known to have or can reasonably be expected to have less leakage
integrity than the average of the system, the cable operator
demonstrates compliance with a cumulative signal leakage index by
showing that 10 log Iinfty is equal to or less than 64 using the
following formula:
eCFR graphic er22fe18.000.gif
View or download PDF
this the fraction of the system cable length actually examined for
leakage sources and is equal to the strand kilometers (strand miles) of
plant tested divided by the total strand kilometers (strand miles) in
the plant;
Ei is the electric field strength in microvolts per meter (µV/m)
measured 3 meters from the leak i; and
n is the number of leaks found of field strength equal to or greater
than 50 µV/m measured pursuant to § 76.609(h).
The sum is carried over all leaks i detected in the cable examined; or
(2) Prior to carriage of signals in the aeronautical radio bands and at
least once each calendar year, with no more than 12 months between
successive tests thereafter, the cable operator demonstrates by
measurement in the airspace that at no point does the field strength
generated by the cable system exceed 10 microvolts per meter (µV/m) RMS
at an altitude of 450 meters above the average terrain of the cable
system. The measurement system (including the receiving antenna) shall
be calibrated against a known field of 10 µV/m RMS produced by a well
characterized antenna consisting of orthogonal resonant dipoles, both
parallel to and one quarter wavelength above the ground plane of a
diameter of two meters or more at ground level. The dipoles shall have
centers collocated and be excited 90 degrees apart. The half-power
bandwidth of the detector shall be 25 kHz. If an aeronautical receiver
is used for this purpose it shall meet the standards of the Radio
Technical Commission for Aeronautics (RCTA) for aeronautical
communications receivers. The aircraft antenna shall be horizontally
polarized. Calibration shall be made in the community unit or, if more
than one, in any of the community units of the physical system within a
reasonable time period to performing the measurements. If data is
recorded digitally the 90th percentile level of points recorded over
the cable system shall not exceed 10 µV/m RMS as indicated above; if
analog recordings is used the peak values of the curves, when smoothed
according to good engineering practices, shall not exceed 10 µV/m RMS.
(b) In paragraphs (a)(1) and (2) of this section the unmodulated test
signal used for analog leakage measurements on the cable plant shall--
(1) Be within the VHF aeronautical band 108-137 MHz or any other
frequency for which the results can be correlated to the VHF
aeronautical band; and
(2) Have an average power level equal to the greater of:
(i) The peak envelope power level of the strongest NTSC or similar
analog cable television signal on the system, or
(ii) 1.2 dB greater than the average power level of the strongest QAM
or similar digital cable television signal on the system.
(c) In paragraphs (a)(1) and (2) of this section, if a modulated test
signal is used for analog leakage measurements, the test signal and
detector technique must, when considered together, yield the same
result as though an unmodulated test signal were used in conjunction
with a detection technique which would yield the RMS value of said
unmodulated carrier.
(d) If a sampling of at least 75% of the cable strand (and including
any portions of the cable system which are known to have or can
reasonably be expected to have less leakage integrity than the average
of the system) as described in paragraph (a)(1) of this section cannot
be obtained by the cable operator or is otherwise not reasonably
feasible, the cable operator shall perform the airspace measurements
described in paragraph (a)(2) of this section.
(e) Prior to providing service to any subscriber on a new section of
cable plant, the operator shall show compliance with either:
(1) The basic signal leakage criteria in accordance with paragraphs
(a)(1) or (2) of this section for the entire plant in operation or
(2) a showing shall be made indicating that no individual leak in the
new section of the plant exceeds 20 µV/m at 3 meters in accordance with
§ 76.609 for analog signals or 17.4 µV/m at 3 meters for digital
signals.
(f) Notwithstanding paragraph (a) of this section, a cable operator
shall be permitted to operate on any frequency which is offset pursuant
to § 76.612 in the frequency band 108-137 MHz for the purpose of
demonstrating compliance with the cable television basic signal leakage
performance criteria.
[ 83 FR 7629 , Feb. 22, 2018]
Goto Section: 76.610 | 76.612
Goto Year: 2019 |
2021
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public