§ 73.811 LPFM power and antenna height requirements.
(a) Maximum facilities. LPFM stations will be authorized to operate
with maximum facilities of 100 watts ERP at 30 meters HAAT. An LPFM
station with a HAAT that exceeds 30 meters will not be permitted to
operate with an ERP greater than that which would result in a 60 dBu
contour of 5.6 kilometers. In no event will an ERP less than one watt
be authorized. No facility will be authorized in excess of one watt ERP
at 450 meters HAAT.
(b) Minimum facilities. LPFM stations may not operate with facilities
less than 50 watts ERP at 30 meters HAAT or the equivalent necessary to
produce a 60 dBu contour that extends at least 4.7 kilometers.