Goto Section: 51.320 | 51.323 | Table of Contents

FCC 51.321
Revised as of October 1, 2010
Goto Year:2009 | 2011
  §  51.321   Methods of obtaining interconnection and access to unbundled
elements under section 251 of the Act.

   (a) Except as provided in paragraph (e) of this section, an incumbent
   LEC shall provide, on terms and conditions that are just, reasonable,
   and nondiscriminatory in accordance with the requirements of this part,
   any technically feasible method of obtaining interconnection or access
   to unbundled network elements at a particular point upon a request by a
   telecommunications carrier.

   (b) Technically feasible methods of obtaining interconnection or access
   to unbundled network elements include, but are not limited to:

   (1) Physical collocation and virtual collocation at the premises of an
   incumbent LEC; and

   (2) Meet point interconnection arrangements.

   (c) A previously successful method of obtaining interconnection or
   access to unbundled network elements at a particular premises or point
   on any incumbent LEC's network is substantial evidence that such method
   is technically feasible in the case of substantially similar network
   premises or points. A requesting telecommunications carrier seeking a
   particular collocation arrangement, either physical or virtual, is
   entitled to a presumption that such arrangement is technically feasible
   if any LEC has deployed such collocation arrangement in any incumbent
   LEC premises.

   (d) An incumbent LEC that denies a request for a particular method of
   obtaining interconnection or access to unbundled network elements on
   the incumbent LEC's network must prove to the state commission that the
   requested method of obtaining interconnection or access to unbundled
   network elements at that point is not technically feasible.

   (e) An incumbent LEC shall not be required to provide for physical
   collocation of equipment necessary for interconnection or access to
   unbundled network elements at the incumbent LEC's premises if it
   demonstrates to the state commission that physical collocation is not
   practical for technical reasons or because of space limitations. In
   such cases, the incumbent LEC shall be required to provide virtual
   collocation, except at points where the incumbent LEC proves to the
   state commission that virtual collocation is not technically feasible.
   If virtual collocation is not technically feasible, the incumbent LEC
   shall provide other methods of interconnection and access to unbundled
   network elements to the extent technically feasible.

   (f) An incumbent LEC shall submit to the state commission, subject to
   any protective order as the state commission may deem necessary,
   detailed floor plans or diagrams of any premises where the incumbent
   LEC claims that physical collocation is not practical because of space
   limitations. These floor plans or diagrams must show what space, if
   any, the incumbent LEC or any of its affiliates has reserved for future
   use, and must describe in detail the specific future uses for which the
   space has been reserved and the length of time for each reservation. An
   incumbent LEC that contends space for physical collocation is not
   available in an incumbent LEC premises must also allow the requesting
   carrier to tour the entire premises in question, not only the area in
   which space was denied, without charge, within ten days of the receipt
   of the incumbent's denial of space. An incumbent LEC must allow a
   requesting telecommunications carrier reasonable access to its selected
   collocation space during construction.

   (g) An incumbent LEC that is classified as a Class A company under
   § 32.11 of this chapter and that is not a National Exchange Carrier
   Association interstate tariff participant as provided in part 69,
   subpart G, shall continue to provide expanded interconnection service
   pursuant to interstate tariff in accordance with § § 64.1401, 64.1402,
   69.121 of this chapter, and the Commission's other requirements.

   (h) Upon request, an incumbent LEC must submit to the requesting
   carrier within ten days of the submission of the request a report
   describing in detail the space that is available for collocation in a
   particular incumbent LEC premises. This report must specify the amount
   of collocation space available at each requested premises, the number
   of collocators, and any modifications in the use of the space since the
   last report. This report must also include measures that the incumbent
   LEC is taking to make additional space available for collocation. The
   incumbent LEC must maintain a publicly available document, posted for
   viewing on the incumbent LEC's publicly available Internet site,
   indicating all premises that are full, and must update such a document
   within ten days of the date at which a premises runs out of physical
   collocation space.

   (i) An incumbent LEC must, upon request, remove obsolete unused
   equipment from their premises to increase the amount of space available
   for collocation.

   [ 61 FR 45619 , Aug. 28, 1996, as amended at  64 FR 23241 , Apr. 30, 1999;
    65 FR 54438 , Sept. 8, 2000;  66 FR 43521 , Aug. 20, 2001]


Goto Section: 51.320 | 51.323

Goto Year: 2009 | 2011
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public