Goto Section: 95.1113 | 95.1117 | Table of Contents

FCC 95.1115
Revised as of October 1, 2009
Goto Year:2008 | 2010
  §  95.1115   General technical requirements.

   (a) Field strength limits. (1) In the 608–614 MHz band, the maximum
   allowable field strength is 200 mV/m, as measured at a distance of 3
   meters, using measuring instrumentation with a CISPR quasi-peak
   detector.

   (2) In the 1395–1400 MHz and 1427–1429.5 MHz bands, the maximum
   allowable field strength is 740 mV/m, as measured at a distance of 3
   meters, using measuring equipment with an averaging detector and a 1
   MHz measurement bandwidth.

   (b) Undesired emissions. (1) Out-of-band emissions below 960 MHz are
   limited to 200 microvolts/meter, as measured at a distance of 3 meters,
   using measuring instrumentation with a CISPR quasi-peak detector.

   (2) Out-of-band emissions above 960 MHz are limited to 500
   microvolts/meter as measured at a distance of 3 meters, using measuring
   equipment with an averaging detector and a 1 MHz measurement bandwidth.

   (c) Emission types. A wireless medical telemetry device may transmit
   any emission type appropriate for communications in this service,
   except for video and voice. Waveforms such as electrocardiograms (ECGs)
   are not considered video.

   (d) Channel use. (1) In the 1395–1400 MHz and 1427–1429.5 MHz bands, no
   specific channels are specified. Wireless medical telemetry devices may
   operate on any channel within the bands authorized for wireless medical
   telemetry use in this part.

   (2) In the 608–614 MHz band, wireless medical telemetry devices
   utilizing broadband technologies such as spread spectrum shall be
   capable of operating within one or more of the following channels of
   1.5 MHz each, up to a maximum of 6 MHz, and shall operate on the
   minimum number of channels necessary to avoid harmful interference to
   any other wireless medical telemetry devices.

   608.0–609.5 MHz

   609.5–611.0 MHz

   611.0–612.5 MHz

   612.5–614.0 MHz

   (3) Channel usage is on a co-primary shared basis only, and channels
   will not be assigned for the exclusive use of any entity.

   (4) Authorized health care providers, in conjunction with the equipment
   manufacturers, must cooperate in the selection and use of frequencies
   in order to reduce the potential for interference with other wireless
   medical telemetry devices, or other co-primary users. Operations in the
   608–614 MHz band (television channel 37) are not protected from
   adjacent band interference from broadcast television operating on
   channels 36 and 38.

   (e) Frequency stability. Manufacturers of wireless medical telemetry
   devices are responsible for ensuring frequency stability such that an
   emission is maintained within the band of operation under all of the
   manufacturer's specified conditions.

   [ 65 FR 44008 , July 17, 2000, as amended at  67 FR 6194 , Feb. 11, 2002;
    68 FR 68547 , Dec. 9, 2003]


Goto Section: 95.1113 | 95.1117

Goto Year: 2008 | 2010
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com