Goto Section: 2.1505 | 2.1509 | Table of Contents
FCC 2.1507
Revised as of October 1, 2005
Goto Year:2004 |
2006
Sec. 2.1507 Test frequencies.
Testing of an EPIRB for compliance outside a shielded room on a distress
frequency is prohibited, since this may interfere with emergency
communications. Therefore, all compliance testing outside a shielded room
should be conducted on one of the pairs of alternate frequencies specified
below:
121.600/243.200 MHz
121.650/243.300 MHz
121.700/243.400 MHz
121.750/243.500 MHz
121.800/243.600 MHz
121.850/243.700 MHz
121.900/243.800 MHz
The above frequencies are to be used for limited testing of EPIRBs for
compliance with FCC Rules, subject to the following conditions:
(a) The testing shall not cause harmful interference to authorized
communications on these frequencies.
(b) The testing shall be coordinated with the nearest FCC district office.
For simplicity, 121.5 MHz and 243 MHz will be used throughout this test
procedure to indicate the alternate test frequency.
Goto Section: 2.1505 | 2.1509
Goto Year: 2004 |
2006
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public