FCC 101.1440 Revised as of October 1, 2005
Goto Year:2004 |
2006
Sec. 101.1440 MVDDS protection of DBS.
(a) An MVDDS licensee shall not begin operation unless it can ensure that
the EPFD from its transmitting antenna at all DBS customers of record
locations is below the values listed for the appropriate region in
Sec. 101.105(a)(4)(ii). Alternatively, MVDDS licensees may obtain a signed
written agreement from DBS customers of record stating that they are aware
of and agree to their DBS system receiving MVDDS signal levels in excess of
the appropriate EPFD limits specified in Sec. 101.105(a)(4)(ii). DBS customers
of record are those who had their DBS receive antennas installed prior to or
within the 30 day period after notification to the DBS operator by the MVDDS
licensee of the proposed MVDDS transmitting antenna site.
(b) MVDDS licensees are required to conduct a survey of the area around its
proposed transmitting antenna site to determine the location of all DBS
customers of record that may potentially be affected by the introduction of
its MVDDS service. The MVDDS licensee must assess whether the signal levels
from its system, under its deployment plans, would exceed the appropriate
EPFD levels in Sec. 101.105(a)(4)(ii) at any DBS customer of record location.
Using EPFD calculations, terrain and building structure characteristics, and
the survey results, an MVDDS licensee must make a determination of whether
its signal level(s) will exceed the EPFD limit at any DBS customer of record
sites. To assist in making this determination, the MVDDS provider can use
the EPFD contour model developed by the Commission and described in Appendix
J of the Memorandum Opinion and Order and Second Report and Order, ET Docket
98–206 or on the OET website at http://www.fcc.gov/oet/dockets/et98-206.
(c) If the MVDDS licensee determines that its signal level will exceed the
EPFD limit at any DBS customer site, it shall take whatever steps are
necessary, up to and including finding a new transmit site, to ensure that
the EPFD limit will not be exceeded at any DBS customer location.
(d) Coordination between MVDDS and DBS licensees. (1) At least 90 days prior
to the planned date of MVDDS commencement of operations, the MVDDS licensee
shall provide the following information to the DBS licensee(s):
(i) Geographic location (including NAD 83 coordinates) of its proposed
station location;
(ii) Maximum EIRP of each transmitting antenna system;
(iii) Height above ground level for each transmitting antenna;
(iv) Antenna type along with main beam azimuth and altitude orientation
information, and description of the antenna radiation pattern;
(v) Description of the proposed service area; and
(vi) Survey results along with a technical description of how it determined
compliance with the appropriate EPFD level at all DBS subscriber locations.
(2) No later than forty-five days after receipt of the MVDDS system
information in paragraph (d)(1) of this section, the DBS licensee(s) shall
provide the MVDDS licensee with a list of only those new DBS customer
locations that have been installed in the 30-day period following the MVDDS
notification and that the DBS licensee believes may receive harmful
interference or where the prescribed EPFD limits may be exceeded. In
addition, the DBS licensee(s) could indicate agreement with the MVDDS
licensee's technical assessment, or identify DBS customer locations that the
MVDDS licensee failed to consider or DBS customer locations where they
believe the MVDDS licensee erred in its analysis and could exceed the
prescribed EPFD limit.
(3) Prior to commencement of operation, the MVDDS licensee must take into
account any new DBS customers or other relevant information provided by DBS
licensees in response to the notification in paragraph (d)(1) of this
section.
(e) Beginning thirty days after the DBS licensees are notified of a
potential MVDDS site in paragraph (d)(1) of this section, the DBS licensees
are responsible for providing information they deem necessary for those
entities who install all future DBS receive antennas on its system to take
into account the presence of MVDDS operations so that these DBS receive
antennas can be located in such a way as to avoid the MVDDS signal. These
later installed DBS receive antennas shall have no further rights of
complaint against the notified MVDDS transmitting antenna(s).
(f) In the event of either an increase in the EPFD contour in any direction
or a major modification as defined in Sec. 1.929 of this chapter, such as the
addition of an antenna, to an MVDDS station, the procedures of paragraphs
(d) and (e) of this section and rights of complaint begin anew. Exceptions
to this are renewal, transfer of control, and assignment of license
applications.
(g) Interference complaints. The MVDDS licensee must satisfy all complaints
of interference to DBS customers of record which are received during a one
year period after commencement of operation of the transmitting facility.
Specifically, the MVDDS licensee must correct interference caused to a DBS
customer of record or cease operation if it is demonstrated that the DBS
customer is receiving harmful interference from the MVDDS system or that the
MVDDS signal exceeds the permitted EPFD level at the DBS customer location.
Subpart Q—Service and Technical Rules for the 70/80/90 GHz Bands
Source: 69 FR 3267 , Jan. 23, 2004, unless otherwise noted.
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.