Sec. 80.813  Installation of automatic-alarm-signal keying device.

    (a) The automatic radiotelegraph alarm signal keyer must be 
installed in the radiotelegraph operating room. It must be possible to 
key, nonsimultaneously, the main transmitter and the reserve 
transmitter, and to permit the device to be taken out of operation at 
any time in order to permit immediate manual transmitter operation. Only 
one control must be provided for each automatic alarm signal keying 
device. This control must be located in the radiotelegraph operating 
room.
    (b) The required automatic radiotelegraph alarm signal keying device 
must be capable of operating efficiently for a continuous period of 1 
hour when energized solely by the reserve power supply.