Sec. 22.565 Transmitting power limits.
The transmitting power of base, mobile and fixed transmitters
operating on the channels listed in Sec. 22.561 must not exceed the
limits in this section.
(a) Maximum ERP. The effective radiated power (ERP) of base and
fixed transmitters must not exceed the applicable limits in this
paragraph under any circumstances.
------------------------------------------------------------------------
Maximum ERP
Frequency range (MHz) (watts)
------------------------------------------------------------------------
152-153.................................................... 1400
157-159.................................................... 150
454-455.................................................... 3500
459-460.................................................... 150
------------------------------------------------------------------------
(b) Basic power limit. Except as provided in paragraph (d) of this
section, the ERP of base transmitters must not exceed 500 Watts.
(c) Height-power limits. Except as provided in paragraph (d) of this
section, the ERP of base transmitters must not exceed the amount that
would result in an average distance to the service contour of 41.6
kilometers (26 miles) for VHF channels or 30.7 kilometers (19 miles) for
UHF channels. The average distance to the service contour is calculated
by taking the arithmetic mean of the distances determined using the
procedures specified in Sec. 22.567 for the eight cardinal radial
directions, excluding cardinal radial directions for which 90% or more
of the distance so calculated is over water.
(d) Encompassed interfering contour areas. Base transmitters are
exempt from the basic power and height-power limits of this section if
the area within their interfering contours is totally encompassed by the
interfering contours of operating co-channel based transmitters
controlled by the same licensee. For the purpose of this paragraph,
operating transmitters are authorized transmitters that are providing
service to subscribers.
(e) Adjacent channel protection. The ERP of base and fixed
transmitters must not exceed 500 Watts if they transmit on channel
454.025 MHz and are located less than 7 kilometers (4.3 miles) from any
Private Radio Services station receiving on adjacent channel 454.0000
MHz.
(f) Mobile transmitters. The transmitter output power of mobile
transmitters must not exceed 60 watts.
(g) Other transmitters. The ERP of dispatch and auxiliary test
transmitters must not exceed 100 watts.
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.