Sec. 15.225 Operation within the band 13.553-13.567 MHz.
(a) The field strength of any emissions within this band shall not
exceed 10,000 microvolts/meter at 30 meters.
(b) The field strength of any emissions appearing outside of this
band shall not exceed the general radiated emission limits shown in
Sec. 15.209.
(c) The frequency tolerance of the carrier signal shall be
maintained within &177;0.01% of the operating frequency over a
temperature variation of -20 degrees to +50 degrees C at normal
[[Page 658]]
supply voltage, and for a variation in the primary supply voltage from
85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be
performed using a new battery.