Sec. 15.211 Tunnel radio systems.
An intentional radiator utilized as part of a tunnel radio system
may operate on any frequency provided it meets all of the following
conditions:
[[Page 655]]
(a) Operation of a tunnel radio system (intentional radiator and all
connecting wires) shall be contained solely within a tunnel, mine or
other structure that provides attenuation to the radiated signal due to
the presence of naturally surrounding earth and/or water.
(b) Any intentional or unintentional radiator external to the
tunnel, mine or other structure, as described in paragraph (a) of this
section, shall be subject to the other applicable regulations contained
within this part.
(c) The total electromagnetic field from a tunnel radio system on
any frequency or frequencies appearing outside of the tunnel, mine or
other structure described in paragraph (a) of this section, shall not
exceed the limits shown in Sec. 15.209 when measured at the specified
distance from the surrounding structure, including openings. Particular
attention shall be paid to the emissions from any opening in the
structure to the outside environment. When measurements are made from
the openings, the distances shown in Sec. 15.209 refer to the distance
from the plane of reference which fits the entire perimeter of each
above ground opening.
(d) The conducted limits in Sec. 15.207 apply to the radiofrequency
voltage on the public utility power lines outside of the tunnel.