Sec. 101.131 Transmitter construction and installation.
(a) The equipment at the operating and transmitting positions must
be so installed and protected that it is not accessible to, or capable
of being operated by, persons other than those duly authorized by the
licensee.
(b) In any case where the maximum modulating frequency of a
transmitter is prescribed by the Commission, the transmitter must be
equipped with a low-pass or band-pass modulation filter of suitable
performance characteristics. In those cases where a modulation limiter
is employed, the modulation filter must be installed between the
transmitter stage in which limiting is effected and the modulated stage
of the transmitter.
(c) Each transmitter employed in these services must be equipped
with an appropriately labeled pilot lamp or meter which will provide
continuous visual indication at the transmitter when its control
circuits have been placed in a condition to activate the transmitter. In
addition, facilities must be provided at each transmitter to permit the
transmitter to be turned on and off independently of any remote control
circuits associated therewith.
(d) At each transmitter control point the following facilities must
be installed:
(1) A carrier operated device which will provide continuous visual
indication when the transmitter is radiating, or, in lieu thereof, a
pilot lamp or meter which will provide continuous visual indication when
the transmitter control circuits have been placed in a condition to
activate the transmitter; and
(2) Facilities which will permit the operator to turn transmitter
carrier on and off at will.
(e) Transmitter control circuits from any control point must be so
installed that grounding or shorting any line in the control circuit
will not cause the transmitter to radiate: provided, however, That this
provision will not be
[[Page 771]]
applicable to control circuits of stations which normally operate with
continuous radiation or to control circuits which are under the
effective operational control of responsible operating personnel 24
hours per day.
Goto Section: 101.129 | 101.133
Goto Year: 1996 |
1998
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public