Search for this:
 Search these answers
21 through 30 of 51 similar documents, best matches first.
<<previous   Page: 1 2 3 4 5 6   next>>
21: Hallikainen Instruments Continuous Viscometer
be noted that the pump and capillary tube, as well os the heat exchanger, are immersed in o constant temperature oil bath. The tem,perature of this both is regulated ...
http://plaintext.hallikainen.org/org/hi/brochures/1077.pdf
65%*******___
Size: 5.0M
Depth: 2
Find Similar
Match Info
Show Parents
22: Halinco hi-Lights - Volume 2, Number 8 - September 30, 1962
We have signed a liceneing agreement with Sun Oil Gompany enabling ue to manufacture a 50% Boiling Point Analyzer that wae developed in Sun's laboratory. be weil ...
http://plaintext.hallikainen.org/...hi/newsletter/620930.pdf
65%*******___
Size: 372K
Depth: 2
Find Similar
Match Info
Show Parents
23: Hallikainen Instruments Diacon Moisture Analyzer Model 1482
with continuous indication or recordiw as may be required. In liquid service, the DIACON ANALYZER functions directly with the sample in the liquid phase at line pressure ...
http://plaintext.hallikainen.org/org/hi/brochures/1482.pdf
58%******____
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
24: Halinco hi-Lights - Volume 2, Number 4 - May 29, 1962
draw a small sample from one of the refinery-product lines and analyze it for Initial Boiling Point or End Point temperature. The refinery operator can read the Analyzer ...
http://plaintext.hallikainen.org/...hi/newsletter/620529.pdf
57%******____
Size: 180K
Depth: 2
Find Similar
Match Info
Show Parents
25: Hallikainen hi-lights - Volume 4, Number 6 - June 30, 1963
for the past year and will serve on the board of directors for the com- ing year. Refrigerated Boiling Point Analyzer? Those Estes Refrigeration men have been working ...
http://plaintext.hallikainen.org/...hi/newsletter/630630.pdf
56%******____
Size: 216K
Depth: 2
Find Similar
Match Info
Show Parents
26: Hallikainen Instruments Sliding Plate Viscometer Model 1113
40/50 penetration paving asphalts. At 77°F the range is from Grade 3 liquid asphalts to zere penetration paving asphalts. Since the shear rate may be accurately determined, ...
http://plaintext.hallikainen.org/org/hi/brochures/1113.pdf
56%******____
Size: 9.0M
Depth: 2
Find Similar
Match Info
Show Parents
27: Hallikainen hi-lights - Volume 10, Number 5 - September 1970
Analyzer, Color Analyzer, l%eze Point :Analyzer, Gravitrol Density Analyzer,Diacon %Atilyzer. Designed for continuous on-stream processes, the analyzers have become ...
http://plaintext.hallikainen.org/...hi/newsletter/700900.pdf
56%******____
Size: 974K
Depth: 2
Find Similar
Match Info
Show Parents
28: Hallikainen Instruments Coalescer Model 133652
of 16O'F. The element consists of o molded gloss fibre suitable for use on 011 streams from gasoline to and including gos oils. The COALESCER has been designed to ...
http://plaintext.hallikainen.org/org/hi/brochures/133652.pdf
56%******____
Size: 2.6M
Depth: 2
Find Similar
Match Info
Show Parents
29: Hallikainen Instruments In-Line Viscometer Models 1431 and 1477
viscosity to i 1% of span with a repeatability of i 1% of the span. No need to provide a sample stream to the analyzer. The complete unit is installed in the line ...
http://plaintext.hallikainen.org/org/hi/brochures/1477.pdf
56%******____
Size: 3.0M
Depth: 2
Find Similar
Match Info
Show Parents
30: Halinco hi-Lights - Volume 3, Number 1, January 31, 1963
the Microviscometer and the Jet-Stir Impeller to our line in 1955, and we started manufacturing the Acid Analyzer on the Tide- water Oil Design that same year. In ...
http://plaintext.hallikainen.org/...hi/newsletter/630131.pdf
56%******____
Size: 160K
Depth: 2
Find Similar
Match Info
Show Parents
21 through 30 of 51 similar documents, best matches first.
<<previous   Page: 1 2 3 4 5 6   next>>
Texis & Webinator Copyright (c) 2003 THUNDERSTONE - EPI, Inc.