11: Hallikainen Instruments Process Cloud Point Analyzer Model 1466
15 method. Detection is not affected by the water content or color of the sample. The analyzer has CI cloud point temperature range from -30-F to +55*F (-35-C to ...
http://plaintext.hallikainen.org/org/hi/brochures/1466.pdf
47%*****_____
Size: 3.2M
Depth: 2
Find Similar
Match Info
Show Parents
12: Hallikainen Instruments Continuous Viscometer
is o large capacity Y strainer that provides o filtered sample to the instrument. A constant sample flow rate is achieved with the precision metering pump driven ...
http://plaintext.hallikainen.org/org/hi/brochures/1077.pdf
46%*****_____
Size: 5.0M
Depth: 2
Find Similar
Match Info
Show Parents
13: Hallikainen Instruments Diacon Moisture Analyzer Model 1482
the ana- lyzer sample stream is often obtained by a pressure drop across a control valve or pump, the effluent sample thereby being returned to the process line. ...
http://plaintext.hallikainen.org/org/hi/brochures/1482.pdf
46%*****_____
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
14: Halinco hi-Lights - Volume 2, Number 6 - July 27, 1962
pumped into the Viscometer. The pump provides a constant low flow of 64 ml./min. or about 1 gallon of sample per hour. The sample passe8 through an 18 foot long heat ...
http://plaintext.hallikainen.org/...hi/newsletter/620727.pdf
46%*****_____
Size: 376K
Depth: 2
Find Similar
Match Info
Show Parents
15: Halinco hi-Lights - Volume 2, Number 8 - September 30, 1962
We have signed a liceneing agreement with Sun Oil Gompany enabling ue to manufacture a 50% Boiling Point Analyzer that wae developed in Sun's laboratory. be weil ...
http://plaintext.hallikainen.org/...hi/newsletter/620930.pdf
46%*****_____
Size: 372K
Depth: 2
Find Similar
Match Info
Show Parents
16: Halinco hi-Lights - Volume 3, Number 2 - February 28, 1963
year. They are going to show a 50% Analyzer, a Kinetic Vapor Pressure Analyzer, an Initial Boiling Point Analyzer and a Laboratory Viscometer. Mr. Schimbor will spend ...
http://plaintext.hallikainen.org/...hi/newsletter/630228.pdf
46%*****_____
Size: 341K
Depth: 2
Find Similar
Match Info
Show Parents
17: Hallikainen Instruments Gravitrol Density Analyzer Mark IV Model ...
milk. The need for versatility combined with high accuracy and increased sensitivity has led to constant im- provements, both in design and performance. The Mark ...
http://plaintext.hallikainen.org/...i/brochures/gr400967.pdf
44%****______
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
18: Hallikainen Instruments Ultraviolet Analyzer Model 1272
the electronic unit. In addition to these main units there are the test switch, test meter, and a constant voltage transformer (transformer used in applications re- ...
http://plaintext.hallikainen.org/org/hi/brochures/1272.pdf
37%****______
Size: 3.0M
Depth: 2
Find Similar
Match Info
Show Parents
19: Halinco hi-Lights - Volume 2, Number 4 - May 29, 1962
draw a small sample from one of the refinery-product lines and analyze it for Initial Boiling Point or End Point temperature. The refinery operator can read the Analyzer ...
http://plaintext.hallikainen.org/...hi/newsletter/620529.pdf
37%****______
Size: 180K
Depth: 2
Find Similar
Match Info
Show Parents
20: Hallikainen Instruments Freezing Point Analyzer Model 1470
On-stream analysis eliminates laboratory time and cost of performing purity tests by the standard ASTM D 1015-55 method. Correction of off-specification products ...
http://plaintext.hallikainen.org/...brochures/fpa100-468.pdf
37%****______
Size: 2.4M
Depth: 2
Find Similar
Match Info
Show Parents