Search for this:
 Search these answers
11 through 20 of 32 similar documents, best matches first.
<<previous   Page: 1 2 3 4   next>>
11: Hallikainen Instruments Continuous Viscometer
In this application, the closer control achieves a saving of 1 % of premium furnace oil from a fuel oil stream of 17,000 Bbls/day. PRINCIPLE OF OPERATION The Hallikainen ...
http://plaintext.hallikainen.org/org/hi/brochures/1077.pdf
64%******____
Size: 5.0M
Depth: 2
Find Similar
Match Info
Show Parents
12: Hallikainen Instruments Diacon Moisture Analyzer Model 1482
may be required. In liquid service, the DIACON ANALYZER functions directly with the sample in the liquid phase at line pressure without a vaporizerorcarrier gas. ...
http://plaintext.hallikainen.org/org/hi/brochures/1482.pdf
59%******____
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
13: Hallikainen Instruments Automatic Macrocombustion Apparatus For ...
oxide and then through tubes containing Ascarite and Dehydrite. This pre-treatment removes carbon dioxide and water vapor from the air and oxygen which are used in ...
http://plaintext.hallikainen.org/org/hi/brochures/1325.pdf
56%******____
Size: 4.7M
Depth: 2
Find Similar
Match Info
Show Parents
14: Hallikainen Instruments Freezing Point Analyzer Model 1470
in sweepstream. Total flow through sample cell depends on product. With p-xylene, sample must be 70-F. and dry. Pressure drop across cell is approximately 1 to 2 ...
http://plaintext.hallikainen.org/...brochures/fpa100-468.pdf
56%******____
Size: 2.4M
Depth: 2
Find Similar
Match Info
Show Parents
15: Hallikainen Instruments Continuous Analyzer For Sulfuric Acid ...
The restrictors are used to reduce the pressure drop across the air loaded flow con- trol valve to produce a smoother acid flow. The pressure gauge on the down stream ...
http://plaintext.hallikainen.org/org/hi/brochures/1024.pdf
56%******____
Size: 5.0M
Depth: 2
Find Similar
Match Info
Show Parents
16: Hallikainen Instruments Vapor Pressure Analyzer Model 1354
being used for in-line blending where Reid vapor pressure is a product specification ADVANTAGES Fast speed of response Simplicity in design Sturdy construction Precise ...
http://plaintext.hallikainen.org/org/hi/brochures/1354.pdf
56%******____
Size: 2.5M
Depth: 2
Find Similar
Match Info
Show Parents
17: Hallikainen Instruments In-Line Viscometer Models 1431 and 1477
analyzer. The complete unit is installed in the line and forms a part of the process line. All components includ- ing filter, metering pump and capillary are housed ...
http://plaintext.hallikainen.org/org/hi/brochures/1477.pdf
56%******____
Size: 3.0M
Depth: 2
Find Similar
Match Info
Show Parents
18: Hallikainen Instruments Color Analyzer Model 1274
Sample slip stream connections ore %" tubing or I/," pipe. Sample consumption is about 100 ml/min. Sample temperature should not exceed 21O'F. The maximum sample ...
http://plaintext.hallikainen.org/org/hi/brochures/1274.pdf
47%*****_____
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
19: Hallikainen Instruments Product Summary
Absolute viscosity is measured by this instrument using the method of measuring differential pressure across a capillary tube. By maintaining a constant flow rate ...
http://plaintext.hallikainen.org/...hi/brochures/summary.pdf
47%*****_____
Size: 2.0M
Depth: 2
Find Similar
Match Info
Show Parents
20: Hallikainen Instruments Ultraviolet Analyzer Model 1272
source is divided into a measuring beam and a reference beam. The measuring beam passes through the sample cell and falls on one phototube, and the reference beam ...
http://plaintext.hallikainen.org/org/hi/brochures/1272.pdf
46%*****_____
Size: 3.0M
Depth: 2
Find Similar
Match Info
Show Parents
11 through 20 of 32 similar documents, best matches first.
<<previous   Page: 1 2 3 4   next>>
Texis & Webinator Copyright (c) 2003 THUNDERSTONE - EPI, Inc.