11: Hallikainen Instruments Diacon Moisture Analyzer Model 1482
At such time as the moisture content of the stream (percent of saturation as established by cell temperature with liquid; by pressure and temperature with gas) decreases, ...
http://plaintext.hallikainen.org/org/hi/brochures/1482.pdf
47%*****_____
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
12: Hallikainen Instruments Automatic Osmometer Model 1361
bridge circuit. The bridge unbalance signal is amplified by a high- gain amplifier to control o pair of small thyratrons, which furnish o proportional current for ...
http://plaintext.hallikainen.org/org/hi/brochures/1361.pdf
47%*****_____
Size: 4.9M
Depth: 2
Find Similar
Match Info
Show Parents
13: Halinco hi-Lights - Volume 2, Number 7 - August 31, 1962
heater which wffl x8- epond to and rectify changes in teDlp8rature b8youd the desired Unite. With our control- lers we uee a r8eiatance thermaneter a8 a sensiug el8m8ut. ...
http://plaintext.hallikainen.org/...hi/newsletter/620831.pdf
46%*****_____
Size: 337K
Depth: 2
Find Similar
Match Info
Show Parents
14: Hallikainen Instruments Reflux End Point Analyzer Model 1353A
etc. GE5CRlPTlON OF OPERATION The most prominent use of the analyzer is in measuring the temperature of products coming from debutan- izers. deproponizers, etc. in ...
http://plaintext.hallikainen.org/org/hi/brochures/1353a.pdf
46%*****_____
Size: 2.8M
Depth: 2
Find Similar
Match Info
Show Parents
15: Hallikainen Instruments Sliding Plate Viscometer Model 1113
means of quickly operated spring clamps, one of the glass plates is clamped to the MICROVISCOMETER Model 1113 frame and the other to the loading device. It is not ...
http://plaintext.hallikainen.org/org/hi/brochures/1113.pdf
46%*****_____
Size: 9.0M
Depth: 2
Find Similar
Match Info
Show Parents
16: Hallikainen Instruments Boiling Point Analyzer Model 1340
bv-pass, one for water, an Mid-Range Model Sun Oil Company Design Model 1340 The Mid-Range Model BOILING POINT ANALYZER operates in the 30% to 70% recovered range. ...
http://plaintext.hallikainen.org/org/hi/brochures/1340.pdf
46%*****_____
Size: 3.2M
Depth: 2
Find Similar
Match Info
Show Parents
17: Halinco hi-Lights - Volume 1, Number 6 - October 27, 1961
oils which previously could not be analyzed in the instrument. He says also that they are working on a model of the BPA that will operate under pressures other than ...
http://plaintext.hallikainen.org/...hi/newsletter/611027.pdf
45%*****_____
Size: 193K
Depth: 2
Find Similar
Match Info
Show Parents
18: Hallikainen Hi-Lights
New babies! Volume 3, Number 10 - October 31, 1963 - Ship carrying constant temperature bath sinks in France; D. J. Pompeo Memorial Fund; Christmas parties coming; ...
http://plaintext.hallikainen.org/org/hi/newsletter/
44%****______
Size: 40K
Depth: 1
Find Similar
Match Info
Show Parents
19: Halinco hi-Lights - Volume 3, Number 2 - February 28, 1963
recorder in the control room for indication and record. The reccrder is provided with high and low alarm functions on the temper- ature pen to signal if the vapor ...
http://plaintext.hallikainen.org/...hi/newsletter/630228.pdf
38%****______
Size: 341K
Depth: 2
Find Similar
Match Info
Show Parents
20: Hallikainen Instruments Product Brochures
Viscocity Bath Models 1087, 1115, and 1155 Laboratory Cloud Point Analyzer Model 1433 LoTemp Constant Temperature Bath Multi-Block Tube Heaters. Document STH 100 ...