11 through 20 of 43 similar documents, best matches first. | ||
<<previous | Page: 1 2 3 4 5 | next>> |
11: | Halinco hi-Lights - Volume 2, Number 6 - July 27, 1962 5 inchee in length depending on the viscosity of the sample to be analyzed. With a constant flow of even temperature sample, a drop in pressure across the capillary ... http://plaintext.hallikainen.org/...hi/newsletter/620727.pdf | 58% Size: 376K Depth: 2 Find Similar Match Info Show Parents |
12: | Hallikainen Instruments Constant Temperature Baths SIllcone 011 (#2co) water Water Water S~hcone 011 (F-1-0173) Medicinal or Light Viscosity Oil Silicone Oil (F-l -0173) Salt (#275) Salt (#275) Salt (#235) Model 1010 ... http://plaintext.hallikainen.org/org/hi/brochures/1124.pdf | 57% Size: 9.1M Depth: 2 Find Similar Match Info Show Parents |
13: | Hallikainen Instruments Gravitrol Density Analyzer Mark IV Model ... of 1OOa/o of the working span *Fore balance transmission signals, linearly related to the density span *Recalibration on site for any density span within the range ... http://plaintext.hallikainen.org/...i/brochures/gr400967.pdf | 57% Size: 2.7M Depth: 2 Find Similar Match Info Show Parents |
14: | Hallikainen Instruments Boiling Point Analyzer - End Point Model ... used on closed loop control to increase product yield. ANALYTICAL INSTRUMENTS FOR CONTINUOUS PROCESSES -~I 4. Intermediate Products - Continuously monitoring the ... http://plaintext.hallikainen.org/org/hi/brochures/1238.pdf | 57% Size: 5.6M Depth: 2 Find Similar Match Info Show Parents |
15: | Hallikainen Instruments Boiling Point Analyzer Model 1340 pump and boiled at o constant heat input. Cooled distillate is removed from the boiler ot o constont rote equal to o percentage of the feed rate by o second metering ... http://plaintext.hallikainen.org/org/hi/brochures/1340.pdf | 57% Size: 3.2M Depth: 2 Find Similar Match Info Show Parents |
16: | Hallikainen Instruments Continuous Analyzer For Sulfuric Acid ... a graph of settled spent alkyla- tion acid in degrees Baumeversuspercent byweight of titratable acidity. Figure 2 shows a flow diagram of one design of the acid analyzerforthe ... http://plaintext.hallikainen.org/org/hi/brochures/1024.pdf | 57% Size: 5.0M Depth: 2 Find Similar Match Info Show Parents |
17: | Halinco hi-Lights - Volume 3, Number 1, January 31, 1963 they are ready for production. Our instruments which sell in the greatest quantity at present are temperature control- lers (Thermotrol, Thermodyne and Resistotrol). ... http://plaintext.hallikainen.org/...hi/newsletter/630131.pdf | 56% Size: 160K Depth: 2 Find Similar Match Info Show Parents |
18: | Hallikainen hi-lights - Volume 4, Number 6 - June-July 1964 specifications. The Falling Ball Viscometer consists of a glass tube and a calibrated ball or float. An oil sample is put in the tube, and the ball is dropped through ... http://plaintext.hallikainen.org/...hi/newsletter/640607.pdf | 56% Size: 268K Depth: 2 Find Similar Match Info Show Parents |
19: | Hallikainen Instruments Automatic Osmometer Model 1361 by means of the inlet and outlet valves. After CI period of about 5 to 10 minutes the camotic pressure can be read on CI mechnical counter to one hundredth of a centimeter ... http://plaintext.hallikainen.org/org/hi/brochures/1361.pdf | 49% Size: 4.9M Depth: 2 Find Similar Match Info Show Parents |
20: | Hallikainen Instruments Filter-Coalescer Model 1363 wets to satisfy several requirements. 1. 2. 3. Large filter surface clrea to minimize the pressure drop produced by very viscous products. Ease of assembly, installation ... http://plaintext.hallikainen.org/org/hi/brochures/1363.pdf | 49% Size: 2.3M Depth: 2 Find Similar Match Info Show Parents |
11 through 20 of 43 similar documents, best matches first. | ||
<<previous | Page: 1 2 3 4 5 | next>> |