Goto Section: 90.687 | 90.691 | Table of Contents
FCC 90.689
Revised as of October 1, 2019
Goto Year:2018 |
2020
§ 90.689 Field strength limits.
(a) For purposes of implementing § § 90.689 through 90.699, predicted 36
and 40 dBµV/m contours shall be calculated using Figure 10 of § 73.699
of this chapter with a correction factor of −9 dB, and predicted 18 and
22 dBµV/m contours shall be calculated using Figure 10a of § 73.699 of
this chapter with a correction factor of −9 dB.
(b) The predicted or measured field strength at any location on the
border of the EA-based service area for EA licensees must not exceed 40
dBuV/m unless all bordering EA licensees agree to a higher field
strength. In the event that this standard conflicts with the EA
licensee's obligation to provide co-channel protection to incumbent
licensees pursuant to § 90.621(b), the requirements of § 90.621(b) shall
prevail.
[ 61 FR 6158 , 6159, Feb. 16, 1996, as amended at 62 FR 41216 , July 31,
1997]
return arrow Back to Top
Goto Section: 90.687 | 90.691
Goto Year: 2018 |
2020
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public