Goto Section: 73.810 | 73.812 | Table of Contents
FCC 73.811
Revised as of October 1, 2018
Goto Year:2017 |
2019
§ 73.811 LPFM power and antenna height requirements.
(a) Maximum facilities. LPFM stations will be authorized to operate
with maximum facilities of 100 watts ERP at 30 meters HAAT. An LPFM
station with a HAAT that exceeds 30 meters will not be permitted to
operate with an ERP greater than that which would result in a 60 dBu
contour of 5.6 kilometers. In no event will an ERP less than one watt
be authorized. No facility will be authorized in excess of one watt ERP
at 450 meters HAAT.
(b) Minimum facilities. LPFM stations may not operate with facilities
less than 50 watts ERP at 30 meters HAAT or the equivalent necessary to
produce a 60 dBu contour that extends at least 4.7 kilometers.
[ 78 FR 2105 , Jan. 9, 2013]
return arrow Back to Top
Goto Section: 73.810 | 73.812
Goto Year: 2017 |
2019
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public