Goto Section: 80.100 | 80.102 | Table of Contents
FCC 80.101
Revised as of October 1, 2016
Goto Year:2015 |
2017
§ 80.101 Radiotelephone testing procedures.
This section is applicable to all stations using telephony except where
otherwise specified.
(a) Station licensees must not cause harmful interference. When
radiation is necessary or unavoidable, the testing procedure described
below must be followed:
(1) The operator must not interfere with transmissions in progress.
(2) The testing station's call sign, followed by the word “test”, must
be announced on the radio-channel being used for the test.
(3) If any station responds “wait”, the test must be suspended for a
minimum of 30 seconds, then repeat the call sign followed by the word
“test” and listen again for a response. To continue the test, the
operator must use counts or phrases which do not conflict with normal
operating signals, and must end with the station's call sign. Test
signals must not exceed ten seconds, and must not be repeated until at
least one minute has elapsed. On the frequency 2182 kHz or 156.800 MHz,
the time between tests must be a minimum of five minutes.
(b) Testing of transmitters must be confined to single frequency
channels on working frequencies. However, 2182 kHz and 156.800 MHz may
be used to contact ship or coast stations as appropriate when signal
reports are necessary. Short tests on 4125 kHz are permitted by vessels
equipped with MF/HF radios to evaluate the compatibility of the
equipment for distress and safety purposes. U.S. Coast Guard stations
may be contacted on 2182 kHz or 156.800 MHz for test purposes only when
tests are being conducted by Commission employees, when FCC-licensed
technicians are conducting inspections on behalf of the Commission,
when qualified technicians are installing or repairing radiotelephone
equipment, or when qualified ship's personnel conduct an operational
check requested by the U.S. Coast Guard. In these cases the test must
be identified as “FCC” or “technical.”
(c) Survival craft transmitter tests must not be made within actuating
range of automatic alarm receivers.
[ 51 FR 31213 , Sept. 2, 1986, as amended at 63 FR 29659 , June 1, 1998;
68 FR 46961 , Aug. 7, 2003]
return arrow Back to Top
Goto Section: 80.100 | 80.102
Goto Year: 2015 |
2017
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public