Goto Section: 22.657 | 22.701 | Table of Contents
FCC 22.659
Revised as of October 1, 2016
Goto Year:2015 |
2017
§ 22.659 Effective radiated power limits.
The purpose of the rules in this section, which limit effective
radiated power (ERP), is to reduce the likelihood that interference to
television reception from public mobile operations on these channels
will occur. The protected TV station locations specified in this
section are the locations of record as of September 1974, and these do
not change even though the TV stations may have been subsequently
relocated.
(a) Maximum ERP. The ERP of base transmitters must not exceed 100 Watts
under any circumstances. The ERP of mobile transmitters must not exceed
60 Watts under any circumstances.
(b) Co-channel protection from base transmitters. The ERP of base
transmitters in the New York-Northeastern New Jersey urban area must
not exceed the limits in the tables referenced in paragraphs (b)(2) and
(b)(3) of this section. The limits depend upon the height above average
terrain of the base transmitter antenna and the distance between the
base transmitter and the nearest protected TV station location in
paragraph (b)(1) of this section.
(1) The protected TV station locations are as follows (all coordinates
are referenced to North American Datum 1983 (NAD83)):
Control transmitter frequency range Protected TV station location
470-476 MHz Washington, DC, 38°57′17.4″ N. Lat. 77°00′15.9″ W. Long.
476-482 MHz Lancaster, PA, 40°15′45.3″ N. Lat. 76°27′47.9″ W. Long.
(2) Tables E-8 and E-9 of this section apply to base transmitters in
the New York-Northeastern New Jersey urban area that transmit on
channels in the 476-482 MHz range.
(3) Tables E-10 and E-11 of this section apply to base transmitters in
the New York-Northeastern New Jersey urban area that transmit on
channels in the 470-476 MHz range.
(c) Adjacent channel protection from base transmitters. The ERP of base
transmitters must not exceed the limits in Table E-12 of this section.
The limits depend upon the height above average terrain of the base
transmitter antenna and the distance between the base transmitter and
the nearest protected TV station location specified in paragraph (c)(1)
of this section.
(1) The protected TV station locations are as follows (all coordinates
are referenced to North American Datum 1983 (NAD83)):
Control transmitter frequency range Protected TV station location TV
channel
470-476 MHz Hanover, NH, 43°42′30.3″ N. Lat. 72°09′14.3″ W. Long (15)
476-482 MHz
482-488 MHz Lancaster, PA, 40°15′45.3″ N. Lat. 76°27′47.9″ W. Long (15)
Scranton, PA, 41°10′58.3″ N. Lat. 75°52′19.7″ W. Long (16)
Hanover, NH, 43°42′30.3″ N. Lat. 72°09′14.3″ W. Long (15)
Note: Coordinates are referenced to North American Datum 1983 (NAD83).
(2) Table E-12 of this section applies to base transmitters in the New
York-Northeastern New Jersey urban area.
Table E-8—Maximum ERP (Watts) for Base Transmitters (HAAT 152 Meters or
Less)
Distance to protected TV station in kilometers (miles) Antenna height
above average terrain in meters (feet)
15
(50) 30
(100) 46
(150) 61
(200) 76
(250) 91
(300) 107
(350) 122
(400) 137
(450) 152
(500)
209 (130) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
201 (125) 1000 1000 1000 1000 1000 1000 1000 850 750 725
193 (120) 1000 1000 1000 1000 900 750 675 600 550 500
185 (115) 1000 1000 800 725 600 525 475 425 375 350
177 (110) 850 700 600 500 425 375 325 300 275 225
169 (105) 600 475 400 325 275 250 225 200 175 150
161 (100) 400 325 275 225 175 150 140 125 110 100
153 (95) 275 225 175 125 110 95 80 70 60 50
145 (90) 175 125 100 75 50
See § 22.659(b)(2). This table is for antenna heights of 152 meters (500
feet) or less above average terrain. For antenna heights between those
in the table, use the next higher antenna height. For distances between
those in the table, use the next lower distance.
Table E-9—Maximum ERP (Watts) for Base Transmitters (HAAT More Than 152
Meters)
Distance to protected TV station in kilometers (miles) Antenna height
above average terrain in meters (feet)
152 (500) 305 (1000) 457 (1500) 610 (2000) 762 (2500) 914 (3000)
209 (130) 1000 447 219 117 71 46
193 (120) 500 209 95 50 30 19
177 (110) 225 91 35 19 11 8
161 (100) 100 30 10 5 3 2
153 (95) 50 13 5 3 2 1
See § 22.659(b)(2). This table is for antenna heights of more than 152
meters (500 feet) above average terrain. For intermediate values of
height and/or distance, use linear interpolation to obtain the maximum
permitted ERP.
Table E-10—Maximum ERP (Watts) for Base Transmitters (HAAT 152 Meters
or Less)
Distance to protected TV station in kilometers (miles) Antenna height
above average terrain in meters (feet)
15
(50) 30
(100) 46
(150) 61
(200) 76
(250) 91
(300) 107
(350) 122
(400) 137
(450) 152
(500)
261 (162) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
257 (160) 1000 1000 1000 1000 1000 1000 1000 1000 1000 800
249 (155) 1000 1000 1000 1000 1000 875 775 700 625 575
241 (150) 1000 1000 950 775 725 625 550 500 450 400
233 (145) 850 750 650 575 500 440 400 350 320 300
225 (140) 600 575 465 400 350 300 275 250 230 225
217 (135) 450 400 335 300 255 240 200 185 165 150
209 (130) 350 300 245 200 185 160 145 125 120 100
201 (125) 225 200 170 150 125 110 100 90 80 75
193 (120) 175 150 125 105 90 80 70 60 55 50
See § 22.659(b)(3). This table applies for antenna heights of 152 meters
(500 feet) or less above average terrain. For antenna heights between
those in the table, use the next higher antenna height. For distances
between those in the table, use the next lower distance.
Table E-11—Maximum ERP (Watts) for Base Transmitters (HAAT More Than
152 Meters)
Distance to protected TV station in kilometers (miles) Antenna height
above average terrain in meters (feet)
152 (500) 305 (1000) 457 (1500) 610 (2000) 762 (2500) 914 (3000)
261 (162) 1000 501 282 170 110 71
241 (150) 400 209 110 60 36 23
225 (140) 225 102 50 28 16 10
209 (130) 100 48 21 11 7 5
193 (120) 50 19 9 5 3 2
See § 22.659(b)(3). This table is for antenna heights of more than 152
meters (500 feet) above average terrain. For intermediate values of
height and/or distance, use linear interpolation to obtain the maximum
permitted ERP.
Table E-12—Maximum ERP (Watts) for Base Transmitters
Distance to protected TV station in kilometers (miles) Antenna height
above average terrain in meters (feet)
30
(100) 46
(150) 61
(200) 76
(250) 91
(300) 107
(350) 122
(400) 137
(450) 152
(500)
108 (67) 1000 1000 1000 1000 1000 1000 1000 1000 1000
106 (66) 1000 1000 1000 1000 1000 1000 1000 1000 750
105 (65) 1000 1000 1000 1000 1000 1000 825 650 600
103 (64) 1000 1000 1000 1000 1000 775 625 500 400
101 (63) 1000 1000 1000 1000 440 400 350 320 300
100 (62) 1000 1000 1000 525 375 250 200 150 125
98 (61) 1000 700 450 250 200 125 100 75 50
97 (60) 1000 425 225 125 100 75 50
See § 22.659(c)(2). This table applies to base transmitters in the New
York-Northeastern New Jersey urban areas. This table is for antenna
heights of 152 meters (500 feet) or less above average terrain. For
antenna heights between those in the table, use the next higher antenna
height. For distances between those in the table, use the next lower
distance.
[ 59 FR 59507 , Nov. 17, 1994, as amended at 63 FR 68947 , Dec. 14, 1998]
return arrow Back to Top
Subpart F—Rural Radiotelephone Service
return arrow Back to Top
Goto Section: 22.657 | 22.701
Goto Year: 2015 |
2017
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public