Goto Section: 76.602 | 76.606 | Table of Contents
FCC 76.605
Revised as of October 2, 2015
Goto Year:2014 |
2016
§ 76.605 Technical standards.
(a) The following requirements apply to the performance of a cable
television system as measured at any subscriber terminal with a matched
impedance at the termination point or at the output of the modulating or
processing equipment (generally the headend) of the cable television system
or otherwise as noted. The requirements are applicable to each NTSC or
similar video downstream cable television channel in the system:
(1)(i) The cable television channels delivered to the subscriber's terminal
shall be capable of being received and displayed by TV broadcast receivers
used for off-the-air reception of TV broadcast signals, as authorized under
part 73 of this chapter; and
(ii) Cable television systems shall transmit signals to subscriber premises
equipment on frequencies in accordance with the channel allocation plan set
forth in CEA-542-B: “Standard: Cable Television Channel Identification
Plan,” (Incorporated by reference, see § 76.602).
(2) The aural center frequency of the aural carrier must be 4.5 MHz ±5 kHz
above the frequency of the visual carrier at the output of the modulating or
processing equipment of a cable television system, and at the subscriber
terminal.
(3) The visual signal level, across a terminating impedance which correctly
matches the internal impedance of the cable system as viewed from the
subscriber terminal, shall not be less than 1 millivolt across an internal
impedance of 75 ohms (0 dBmV). Additionally, as measured at the end of a 30
meter (100 foot) cable drop that is connected to the subscriber tap, it
shall not be less than 1.41 millivolts across an internal impedance of 75
ohms ( + 3 dBmV). (At other impedance values, the minimum visual signal
level, as viewed from the subscriber terminal, shall be the square root of
0.0133 (Z) millivolts and, as measured at the end of a 30 meter (100 foot)
cable drop that is connected to the subscriber tap, shall be 2 times the
square root of 0.00662(Z) millivolts, where Z is the appropriate impedance
value.)
(4) The visual signal level on each channel, as measured at the end of a 30
meter cable drop that is connected to the subscriber tap, shall not vary
more than 8 decibels within any six-month interval, which must include four
tests performed in six-hour increments during a 24-hour period in July or
August and during a 24-hour period in January or February, and shall be
maintained within:
(i) 3 decibels (dB) of the visual signal level of any visual carrier within
a 6 MHz nominal frequency separation;
(ii) 10 dB of the visual signal level on any other channel on a cable
television system of up to 300 MHz of cable distribution system upper
frequency limit, with a 1 dB increase for each additional 100 MHz of cable
distribution system upper frequency limit (e.g., 11 dB for a system at
301-400 MHz; 12 dB for a system at 401-500 MHz, etc.); and
(iii) A maximum level such that signal degradation due to overload in the
subscriber's receiver or terminal does not occur.
(5) The rms voltage of the aural signal shall be maintained between 10 and
17 decibels below the associated visual signal level. This requirement must
be met both at the subscriber terminal and at the output of the modulating
and processing equipment (generally the headend). For subscriber terminals
that use equipment which modulate and remodulate the signal (e.g., baseband
converters), the rms voltage of the aural signal shall be maintained between
6.5 and 17 decibels below the associated visual signal level at the
subscriber terminal.
(6) The amplitude characteristic shall be within a range of ±2 decibels from
0.75 MHz to 5.0 MHz above the lower boundary frequency of the cable
television channel, referenced to the average of the highest and lowest
amplitudes within these frequency boundaries. The amplitude characteristic
shall be measured at the subscriber terminal.
(7) The ratio of RF visual signal level to system noise shall not be less
than 43 decibels. For class I cable television channels, the requirements of
this section are applicable only to:
(i) Each signal which is delivered by a cable television system to
subscribers within the predicted Grade B contour for that signal;
(ii) Each signal which is first picked up within its predicted Grade B
contour;
(iii) Each signal that is first received by the cable television system by
direct video feed from a TV broadcast station, a low power TV station, or a
TV translator station.
(8) The ratio of visual signal level to the rms amplitude of any coherent
disturbances such as intermodulation products, second and third order
distortions or discrete-frequency interfering signals not operating on
proper offset assignments shall be as follows:
(i) The ratio of visual signal level to coherent disturbances shall not be
less than 51 decibels for noncoherent channel cable television systems, when
measured with modulated carriers and time averaged; and
(ii) The ratio of visual signal level to coherent disturbances which are
frequency-coincident with the visual carrier shall not be less than 47
decibels for coherent channel cable systems, when measured with modulated
carriers and time averaged.
(9) The terminal isolation provided to each subscriber terminal:
(i) Shall not be less than 18 decibels. In lieu of periodic testing, the
cable operator may use specifications provided by the manufacturer for the
terminal isolation equipment to meet this standard; and
(ii) Shall be sufficient to prevent reflections caused by open-circuited or
short-circuited subscriber terminals from producing visible picture
impairments at any other subscriber terminal.
(10) The peak-to-peak variation in visual signal level caused by undesired
low frequency disturbances (hum or repetitive transients) generated within
the system, or by inadequate low frequency response, shall not exceed 3
percent of the visual signal level. Measurements made on a single channel
using a single unmodulated carrier may be used to demonstrate compliance
with this parameter at each test location.
(11) As of June 30, 1995, the following requirements apply to the
performance of the cable television system as measured at the output of the
modulating or processing equipment (generally the headend) of the system:
(i) The chrominance-luminance delay inequality (or chroma delay), which is
the change in delay time of the chrominance component of the signal relative
to the luminance component, shall be within 170 nanoseconds.
(ii) The differential gain for the color subcarrier of the television
signal, which is measured as the difference in amplitude between the largest
and smallest segments of the chrominance signal (divided by the largest and
expressed in percent), shall not exceed ±20%.
(iii) The differential phase for the color subcarrier of the television
signal which is measured as the largest phase difference in degrees between
each segment of the chrominance signal and reference segment (the segment at
the blanking level of O IRE), shall not exceed ±10 degrees.
(12) As an exception to the general provision requiring measurements to be
made at subscriber terminals, and without regard to the type of signals
carried by the cable television system, signal leakage from a cable
television system shall be measured in accordance with the procedures
outlined in § 76.609(h) and shall be limited as follows:
Frequencies Signal leakage limit (micro-volt/meter) Distance in meters (m)
Less than and including 54 MHz, and over 216 MHz 15 30
Over 54 up to and including 216 MHz 20 3
(b) Cable television systems distributing signals by using methods such as
nonconventional coaxial cable techniques, noncoaxial copper cable
techniques, specialized coaxial cable and fiber optical cable hybridization
techniques or specialized compression techniques or specialized receiving
devices, and which, because of their basic design, cannot comply with one or
more of the technical standards set forth in paragraph (a) of this section,
may be permitted to operate: Provided, That an adequate showing is made
pursuant to § 76.7 which establishes that the public interest is benefited.
In such instances, the Commission may prescribe special technical
requirements to ensure that subscribers to such systems are provided with an
equivalent level of good quality service.
Note 1: Local franchising authorities of systems serving fewer than 1000
subscribers may adopt standards less stringent than those in § 76.605(a). Any
such agreement shall be reduced to writing and be associated with the
system's proof-of-performance records.
Note 2: For systems serving rural areas as defined in § 76.5, the system may
negotiate with its local franchising authority for standards less stringent
than those in § § 76.605(a)(3), 76.605(a)(7), 76.605(a)(8), 76.605(a)(10) and
76.605(a)(11). Any such agreement shall be reduced to writing and be
associated with the system's proof-of-performance records.
Note 3: The requirements of this section shall not apply to devices subject
to the TV interface device rules under part 15 of this chapter.
Note 4: Should subscriber complaints arise from a system failing to meet
§ 76.605(a)(6) prior to December 30, 1999, the cable operator will be
required to provide a converter that will allow the system to meet the
standard immediately at the complaining subscriber's terminal. Further,
should the problem be found to be system-wide, the Commission may order all
converters on the system be changed to meet the standard.
Note 5: Should subscriber complaints arise from a system failing to meet
§ 76.605(a)(10), the cable operator will be required to remedy the complaint
and perform test measurements on § 76.605(a)(10) containing the full number
of channels as indicated in § 76.601(b)(2) at the complaining subscriber's
terminal. Further, should the problem be found to be system-wide, the
Commission may order that the full number of channels as indicated in
§ 76.601(b)(2) be tested at all required locations for future
proof-of-performance tests.
Note 6: No State or franchising authority may prohibit, condition, or
restrict a cable system's use of any type of subscriber equipment or any
transmission technology.
[ 37 FR 3278 , Feb. 12, 1972]
Editorial Note: For Federal Register citations affecting § 76.605 see the
List of CFR Sections Affected, which appears in the Finding Aids section of
the printed volume and at www.fdsys.gov.
return arrow Back to Top
Goto Section: 76.602 | 76.606
Goto Year: 2014 |
2016
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public