Goto Section: 15.237 | 15.240 | Table of Contents
FCC 15.239
Revised as of October 2, 2015
Goto Year:2014 |
2016
§ 15.239 Operation in the band 88-108 MHz.
(a) Emissions from the intentional radiator shall be confined within a band
200 kHz wide centered on the operating frequency. The 200 kHz band shall lie
wholly within the frequency range of 88-108 MHz.
(b) The field strength of any emissions within the permitted 200 kHz band
shall not exceed 250 microvolts/meter at 3 meters. The emission limit in
this paragraph is based on measurement instrumentation employing an average
detector. The provisions in § 15.35 for limiting peak emissions apply.
(c) The field strength of any emissions radiated on any frequency outside of
the specified 200 kHz band shall not exceed the general radiated emission
limits in § 15.209.
(d) A custom built telemetry intentional radiator operating in the frequency
band 88-108 MHz and used for experimentation by an educational institute
need not be certified provided the device complies with the standards in
this part and the educational institution notifies the Office of Engineering
and Technology, in writing, in advance of operation, providing the following
information:
(1) The dates and places where the device will be operated;
(2) The purpose for which the device will be used;
(3) A description of the device, including the operating frequency, RF power
output, and antenna; and,
(4) A statement that the device complies with the technical provisions of
this part.
[ 54 FR 17714 , Apr. 25, 1989; 54 FR 32340 , Aug. 7, 1989; 80 FR 53750 , Sept.
8, 2015]
return arrow Back to Top
Goto Section: 15.237 | 15.240
Goto Year: 2014 |
2016
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public