Goto Section: 17.45 | 17.48 | Table of Contents
FCC 17.47
Revised as of December 4, 2012
Goto Year:2011 |
2013
§ 17.47 Inspection of antenna structure lights and associated control
equipment.
The owner of any antenna structure which is registered with the
Commission and has been assigned lighting specifications referenced in
this part:
(a)(1) Shall make an observation of the antenna structure's lights at
least once each 24 hours either visually or by observing an automatic
properly maintained indicator designed to register any failure of such
lights, to insure that all such lights are functioning properly as
required; or alternatively,
(2) Shall provide and properly maintain an automatic alarm system
designed to detect any failure of such lights and to provide indication
of such failure to the owner.
(b) Shall inspect at intervals not to exceed 3 months all automatic or
mechanical control devices, indicators, and alarm systems associated
with the antenna structure lighting to insure that such apparatus is
functioning properly.
[ 61 FR 4363 , Feb. 6, 1996]
return arrow Back to Top
Goto Section: 17.45 | 17.48
Goto Year: 2011 |
2013
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public