Goto Section: 17.45 | 17.48 | Table of Contents

FCC 17.47
Revised as of December 4, 2012
Goto Year:2011 | 2013
  §  17.47   Inspection of antenna structure lights and associated control
equipment.

   The owner of any antenna structure which is registered with the
   Commission and has been assigned lighting specifications referenced in
   this part:

   (a)(1) Shall make an observation of the antenna structure's lights at
   least once each 24 hours either visually or by observing an automatic
   properly maintained indicator designed to register any failure of such
   lights, to insure that all such lights are functioning properly as
   required; or alternatively,

   (2) Shall provide and properly maintain an automatic alarm system
   designed to detect any failure of such lights and to provide indication
   of such failure to the owner.

   (b) Shall inspect at intervals not to exceed 3 months all automatic or
   mechanical control devices, indicators, and alarm systems associated
   with the antenna structure lighting to insure that such apparatus is
   functioning properly.

   [ 61 FR 4363 , Feb. 6, 1996]

   return arrow Back to Top


Goto Section: 17.45 | 17.48

Goto Year: 2011 | 2013
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public