Goto Section: 17.237 | 17.240 | Table of Contents
FCC 17.239
Revised as of December 4, 2012
Goto Year:2011 |
2013
§ 15.239 Operation in the band 88-108 MHz.
(a) Emissions from the intentional radiator shall be confined within a
band 200 kHz wide centered on the operating frequency. The 200 kHz band
shall lie wholly within the frequency range of 88-108 MHz.
(b) The field strength of any emissions within the permitted 200 kHz
band shall not exceed 250 microvolts/meter at 3 meters. The emission
limit in this paragraph is based on measurement instrumentation
employing an average detector. The provisions in § 15.35 for limiting
peak emissions apply.
(c) The field strength of any emissions radiated on any frequency
outside of the specified 200 kHz band shall not exceed the general
radiated emission limits in § 15.209.
(d) A custom built telemetry intentional radiator operating in the
frequency band 88-108 MHz and used for experimentation by an
educational institute need not be certified provided the device
complies with the standards in this part and the educational
institution notifies the Engineer in Charge of the local FCC office, in
writing, in advance of operation, providing the following information:
(1) The dates and places where the device will be operated;
(2) The purpose for which the device will be used;
(3) A description of the device, including the operating frequency, RF
power output, and antenna; and,
(4) A statement that the device complies with the technical provisions
of this part.
[ 54 FR 17714 , Apr. 25, 1989; 54 FR 32340 , Aug. 7, 1989]
Goto Section: 17.237 | 17.240
Goto Year: 2011 |
2013
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public