§ 15.252 Operation of wideband vehicular radar systems within the bands
16.2-17.7 GHz and 23.12-29.0 GHz.
(a) Operation under this section is limited to field disturbance
sensors that are mounted in terrestrial transportation vehicles.
Terrestrial use is limited to earth surface-based, non-aviation
applications. Operation within the 16.2-17.7 GHz band is limited to
field disturbance sensors that are used only for back-up assistance and
that operate only when the vehicle is engaged in reverse.
(1) The -10 dB bandwidth of the fundamental emission shall be located
within the 16.2-17.7 GHz band or within the 23.12-29.0 GHz band,
exclusive of the 23.6-24.0 GHz restricted band, as appropriate, under
all conditions of operation including the effects from stepped
frequency, frequency hopping or other modulation techniques that may be
employed as well as the frequency stability of the transmitter over
expected variations in temperature and supply voltage.
(2) The -10 dB bandwidth of the fundamental emission shall be 10 MHz or
greater. For transmitters that employ frequency hopping, stepped
frequency or similar modulation types, measurement of the -10 dB
minimum bandwidth specified in this paragraph shall be made with the
frequency hop or step function disabled and with the transmitter
operating continuously at a fundamental frequency following the
provisions of § 15.31(m).
(3) For systems operating in the 23.12-29.0 GHz band, the frequencies
at which the highest average emission level and at which the highest
peak level emission appear shall be greater than 24.075 GHz.
(4) These devices shall operate only when the vehicle is operating,
e.g. , the engine is running. Operation shall occur only upon specific
activation, such as upon starting the vehicle, changing gears, or
engaging a turn signal. The operation of these devices shall be related
to the proper functioning of the transportation vehicle, e.g. ,
collision avoidance.
(b) Emissions from a transmitter operating under this section shall not
exceed the following equivalent isotropically radiated power (EIRP)
density levels:
(1) For transmitters operating in the 16.2-17.7 GHz band, the RMS
average radiated emissions above 960 MHz from a device operating under
the provisions of this section shall not exceed the following EIRP
limits based on measurements using a 1 MHz resolution bandwidth:
Frequency in MHz EIRP in dBm
960-1610 -75.3
1610-16,200 -61.3
16,200-17,700 -41.3
Above 17,700 -61.3
(2) For transmitters operating in the 23.12-29.0 GHz band, the RMS
average radiated emissions above 960 MHz from a device operating under
the provisions of this section shall not exceed the following EIRP
limits based on measurements using a 1 MHz resolution bandwidth:
Frequency in MHz EIRP in dBm
960-1610 -75.3
1610-23,120 -61.3
23,120-23,600 -41.3
23,600-24,000 -61.3
24,000-29,000 -41.3
Above 29,000 --61.3
(3) In addition to the radiated emission limits specified in the tables
in paragraphs (b)(1) and (b)(2) of this section, transmitters operating
under the provisions of this section shall not exceed the following RMS
average EIRP limits when measured using a resolution bandwidth of no
less than 1 kHz:
Frequency in MHz EIRP in dBm
1164-1240 -85.3
1559-1610 -85.3
(4) There is a limit on the peak level of the emissions contained
within a 50 MHz bandwidth centered on the frequency at which the
highest radiated emission occurs and this 50 MHz bandwidth must be
contained within the 16.2-17.7 GHz band or the 24.05-29.0 GHz band, as
appropriate. The peak EIRP limit is 20 log (RBW/50) dBm where RBW is
the resolution bandwidth in MHz employed by the measurement instrument.
RBW shall not be lower than 1 MHz or greater than 50 MHz. Further, RBW
shall not be greater than the -10 dB bandwidth of the device under
test. For transmitters that employ frequency hopping, stepped frequency
or similar modulation types, measurement of the -10 dB minimum
bandwidth specified in this paragraph shall be made with the frequency
hop or step function disabled and with the transmitter operating
continuously at a fundamental frequency. The video bandwidth of the
measurement instrument shall not be less than RBW. The limit on peak
emissions applies to the 50 MHz bandwidth centered on the frequency at
which the highest level radiated emission occurs. If RBW is greater
than 3 MHz, the application for certification shall contain a detailed
description of the test procedure, the instrumentation employed in the
testing, and the calibration of the test setup.
(5) Radiated emissions at or below 960 MHz shall not exceed the
emission levels in § 15.209.
(6) Emissions from digital circuitry used to enable the operation of
the transmitter may comply with the limits in § 15.209 provided it can
be clearly demonstrated that those emissions are due solely to
emissions from digital circuitry contained within the transmitter and
the emissions are not intended to be radiated from the transmitter's
antenna. Emissions from associated digital devices, as defined in
§ 15.3(k) , e.g. , emissions from digital circuitry used to control
additional functions or capabilities other than the operation of the
transmitter, are subject to the limits contained in subpart B of this
part. Emissions from these digital circuits shall not be employed in
determining the -10 dB bandwidth of the fundamental emission or the
frequency at which the highest emission level occurs.
(c) Measurement procedures:
(1) All emissions at and below 960 MHz are based on measurements
employing a CISPR quasi-peak detector. Unless otherwise specified, all
RMS average emission levels specified in this section are to be
measured utilizing a 1 MHz resolution bandwidth with a one millisecond
dwell over each 1 MHz segment. The frequency span of the analyzer
should equal the number of sampling bins times 1 MHz and the sweep rate
of the analyzer should equal the number of sampling bins times one
millisecond. The provision in § 15.35(c) that allows emissions to be
averaged over a 100 millisecond period does not apply to devices
operating under this section. The video bandwidth of the measurement
instrument shall not be less than the resolution bandwidth and trace
averaging shall not be employed. The RMS average emission measurement
is to be repeated over multiple sweeps with the analyzer set for
maximum hold until the amplitude stabilizes.
(2) The peak emission measurement is to be repeated over multiple
sweeps with the analyzer set for maximum hold until the amplitude
stabilizes.
(3) For transmitters that employ frequency hopping, stepped frequency
or similar modulation types, the peak emission level measurement, the
measurement of the RMS average emission levels, the measurement to
determine the center frequency, and the measurement to determine the
frequency at which the highest level emission occurs shall be made with
the frequency hop or step function active. Gated signals may be
measured with the gating active. The provisions of § 15.31(c) continue
to apply to transmitters that employ swept frequency modulation.
(4) The -10 dB bandwidth is based on measurement using a peak detector,
a 1 MHz resolution bandwidth, and a video bandwidth greater than or
equal to the resolution bandwidth.
(5) Alternative measurement procedures may be considered by the
Commission.
[ 70 FR 6775 , Feb. 9, 2005]
Goto Section: 17.251 | 17.253
Goto Year: 2010 |
2012
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public