Goto Section: 10.310 | 10.330 | Table of Contents
FCC 10.320
Revised as of October 1, 2011
Goto Year:2010 |
2012
§ 10.320 Provider alert gateway requirements.
This section specifies the functions that each Participating Commercial
Mobile Service provider is required to support and perform at its CMS
provider gateways.
(a) General. The CMS provider gateway must provide secure, redundant,
and reliable connections to receive Alert Messages from the Federal
alert gateway. Each CMS provider gateway must be identified by a unique
IP address or domain name.
(b) Authentication and validation. The CMS provider gateway must
authenticate interactions with the Federal alert gateway, and validate
Alert Message integrity and parameters. The CMS provider gateway must
provide an error message immediately to the Federal alert gateway if a
validation fails.
(c) Security. The CMS provider gateway must support standardized
IP-based security mechanisms such as a firewall, and support the
defined CMAS "C" interface and associated protocols between the Federal
alert gateway and the CMS provider gateway.
(d) Geographic targeting. The CMS provider gateway must determine
whether the provider has elected to transmit an Alert Message within a
specified alert area and, if so, map the Alert Message to an associated
set of transmission sites.
(e) Message management --(1) Formatting . The CMS provider gateway is
not required to perform any formatting, reformatting, or translation of
an Alert Message, except for transcoding a text, audio, video, or
multimedia file into the format supported by mobile devices.
(2) Reception. The CMS provider gateway must support a mechanism to
stop and start Alert Message deliveries from the Federal alert gateway
to the CMS provider gateway.
(3) Prioritization. The CMS provider gateway must process an Alert
Message on a first in-first out basis except for Presidential Alerts,
which must be processed before all non-Presidential alerts.
(4) Distribution. A Participating CMS provider must deploy one or more
CMS provider gateways to support distribution of Alert Messages and to
manage Alert Message traffic.
(5) Retransmission. The CMS provider gateway must manage and execute
Alert Message retransmission, and support a mechanism to manage
congestion within the CMS provider's infrastructure.
(f) CMS provider profile. The CMS provider gateway will provide profile
information on the CMS provider for the Federal alert gateway to
maintain at the Federal alert gateway. This profile information must be
provided by an authorized CMS provider representative to the Federal
alert gateway administrator. The profile information must include the
data listed in Table 10.320(f) and must comply with the following
procedures:
(1) The information must be provided 30 days in advance of the date
when the CMS provider begins to transmit CMAS alerts.
(2) Updates of any CMS provider profiles must be provided in writing at
least 30 days in advance of the effective change date.
Table 10.320(f)--CMSP Profile on Federal Alert Gateway
Profile parameter Parameter election Description
CMSP Name Unique identification of CMSP.
CMSP gateway Address IP address or Domain Name
Alternate IP address Optional and subject to implementation.
Geo-Location Filtering If "yes" the only CMAM issued in the
listed states will be sent to the CMSP gateway.
If "no", all CMAM will be sent to the CMSP gateway.
If yes, list of states CMAC Geocode for state List can be state name or
abbreviated state name.
Goto Section: 10.310 | 10.330
Goto Year: 2010 |
2012
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public