Goto Section: 90.1213 | 90.1217 | Table of Contents
FCC 90.1215
Revised as of October 1, 2008
Goto Year:2007 |
2009
Sec. 90.1215 Power limits.
The transmitting power of stations operating in the 4940–4990 MHz band must
not exceed the maximum limits in this section.
(a) The peak transmit power should not exceed:
Channel bandwidth
(MHz) Low power peak transmitter power
(dBm) High power peak transmitter power
(dBm)
1 7 20
5 14 27
10 17 30
15 18.8 31.8
20 20 33
High power devices are also limited to a peak power spectral density of 21
dBm per one MHz. High power devices using channel bandwidths other than
those listed above are permitted; however, they are limited to a peak power
spectral density of 21 dBm/MHz. If transmitting antennas of directional gain
greater than 9 dBi are used, both the peak transmit power and the peak power
spectral density should be reduced by the amount in decibels that the
directional gain of the antenna exceeds 9 dBi. However, high power
point-to-point or point-to-multipoint operation (both fixed and
temporary-fixed rapid deployment) may employ transmitting antennas with
directional gain up to 26 dBi without any corresponding reduction in the
transmitter power or spectral density. Corresponding reduction in the peak
transmit power and peak power spectral density should be the amount in
decibels that the directional gain of the antenna exceeds 26 dBi.
(b) Low power devices are also limited to a peak power spectral density of 8
dBm per one MHz. Low power devices using channel bandwidths other than those
listed above are permitted; however, they are limited to a peak power
spectral density of 8 dBm/MHz. If transmitting antennas of directional gain
greater than 9 dBi are used, both the peak transmit power and the peak power
spectral density should be reduced by the amount in decibels that the
directional gain of the antenna exceeds 9 dBi.
(c) The peak transmit power is measured as a conducted emission over any
interval of continuous transmission calibrated in terms of an RMS-equivalent
voltage. If the device cannot be connected directly, alternative techniques
acceptable to the Commission may be used. The measurement results shall be
properly adjusted for any instrument limitations, such as detector response
times, limited resolution bandwidth capability when compared to the emission
bandwidth, sensitivity, etc., so as to obtain a true peak measurement
conforming to the definitions in this paragraph for the emission in
question.
(d) The peak power spectral density is measured as conducted emission by
direct connection of a calibrated test instrument to the equipment under
test. If the device cannot be connected directly, alternative techniques
acceptable to the Commission may be used. Measurements are made over a
bandwidth of one MHz or the 26 dB emission bandwidth of the device,
whichever is less. A resolution bandwidth less than the measurement
bandwidth can be used, provided that the measured power is integrated to
show total power over the measurement bandwidth. If the resolution bandwidth
is approximately equal to the measurement bandwidth, and much less than the
emission bandwidth of the equipment under test, the measured results shall
be corrected to account for any difference between the resolution bandwidth
of the test instrument and its actual noise bandwidth.
[70 CFR 28467, May 18, 2005]
Goto Section: 90.1213 | 90.1217
Goto Year: 2007 |
2009
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public