Goto Section: 80.1013 | 80.1017 | Table of Contents

FCC 80.1015
Revised as of October 1, 2008
Goto Year:2007 | 2009
  Sec.  80.1015   Power supply.

   (a) There must be readily available for use under normal load conditions, a
   power supply sufficient to simultaneously energize the bridge-to-bridge
   transmitter  at  its  required antenna power, and the bridge-to-bridge
   receiver. Under this load condition the voltage of the power supply at the
   power input terminals of the bridge-to-bridge radiotelephone installation
   must not deviate from its rated voltage by more than 10 percent on vessels
   completed on or after March 1, 1957, nor by more than 15 percent on vessels
   completed before that date.

   (b) When the power supply for a nonportable bridge-to-bridge radiotelephone
   installation consists of or includes batteries, they must be installed as
   high above the bilge as practicable, secured against shifting with motion of
   the vessel, and accessible with not less than 26 cm (10 in.) head room.

   (c)  Means  must  be provided for adequately charging any rechargeable
   batteries used in the vessel's bridge-to-bridge radiotelephone installation.
   There must be provided a device which will give a continuous indication of
   the charging current during charging.

   [ 51 FR 31213 , Sept. 2, 1986, as amended at  58 FR 44954 , Aug. 25, 1993]


Goto Section: 80.1013 | 80.1017

Goto Year: 2007 | 2009
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public