Goto Section: 73.810 | 73.812 | Table of Contents

FCC 73.811
Revised as of October 1, 2008
Goto Year:2007 | 2009
  Sec.  73.811   LPFM power and antenna height requirements.

   (a)  LP100  stations:  (1)  Maximum facilities. LP100 stations will be
   authorized  to  operate with maximum facilities of 100 watts effective
   radiated power (ERP) at 30 meters antenna height above average terrain
   (HAAT). An LP100 station with a HAAT that exceeds 30 meters will not be
   permitted to operate with an ERP greater than that which would result in a
   60 dBu contour of 5.6 kilometers. In no event will an ERP less than one watt
   be authorized. No facility will be authorized in excess of one watt ERP at
   450 meters HAAT.

   (2) Minimum facilities. LP100 stations may not operate with facilities less
   than 50 watts ERP at 30 meters HAAT or the equivalent necessary to produce a
   60 dBu contour that extends at least 4.7 kilometers.

   (b) LP10 stations: (1) Maximum Facilities. LP10 stations will be authorized
   to operate with maximum facilities of 10 watts ERP at 30 meters HAAT. An
   LP10 station with a HAAT that exceeds 30 meters will not be permitted to
   operate with an ERP greater than that which would result in a 60 dBu contour
   of 3.2 kilometers. In no event will an ERP less than one watt be authorized.
   No facility will be authorized in excess of one watt ERP at 100 meters HAAT.

   (2) Minimum Facilities. LP10 stations may not operate with less than one
   watt ERP.


Goto Section: 73.810 | 73.812

Goto Year: 2007 | 2009
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public