Sec.  18.307   Conduction limits.

   For the following equipment, when designed to be connected to the public
   utility (AC) power line the radio frequency voltage that is conducted back
   onto the AC power line on any frequency or frequencies shall not exceed the
   limits in the following tables. Compliance with the provisions of this
   paragraph shall be based on the measurement of the radio frequency voltage
   between each power line and ground at the power terminal using a 50 μH/50
   ohms line impedance stabilization network (LISN).

   (a) All Induction cooking ranges and ultrasonic equipment:
   Frequency of emission (MHz) Conducted limit (dBμV)
                               Quasi-peak   Average
   0.009–0.05                  110        —
   0.05–0.15                   90–80*     —
   0.15–0.5                    66 to 56*  56 to 46*
   0.5–5                       56         46
   5–30                        60         50

   *Decreases with the logarithm of the frequency.

   (b) All other part 18 consumer devices:
   Frequency of emission (MHz) Conducted limit (dBμV)
                               Quasi-peak   Average
   0.15–0.5                    66 to 56*  56 to 46*
   0.5–5                       56         46
   5–30                        60         50

   *Decreases with the logarithm of the frequency.

   (c) RF lighting devices:
   Frequency (MHz) Maximum RF line voltage measured with a 50 uH/50 ohm LISN
   (uV)
   Non-consumer equipment:
   0.45 to 1.6 1,000
   1.6 to 30 3,000
   Consumer equipment:
   0.45 to 2.51 250
   2.51 to 3.0 3,000
   3.0 to 30 250

   (d) If testing with a quasi-peak detector demonstrates that the equipment
   complies with the average limits specified in the appropriate table in this
   section, additional testing to demonstrate compliance using an average
   detector is not required.

   (e) These conduction limits shall apply only outside of the frequency bands
   specified in  Sec. 18.301.

   (f) For ultrasonic equipment, compliance with the conducted limits shall
   preclude the need to show compliance with the field strength limits below 30
   MHz unless requested by the Commission.

   (g) The tighter limits shall apply at the boundary between two frequency
   ranges.

   [ 50 FR 36067 , Sept. 5, 1985, as amended at  52 FR 43198 , Nov. 10, 1987;  64 FR 37419 , July 12, 1999;  67 FR 45671 , July 10, 2002]


Goto Section: 18.305 | 18.309

Goto Year: 2006 | 2008
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public