Sec. 15.219 Operation in the band 510–1705 kHz.
(a) The total input power to the final radio frequency stage (exclusive of
filament or heater power) shall not exceed 100 milliwatts.
(b) The total length of the transmission line, antenna and ground lead (if
used) shall not exceed 3 meters.
(c) All emissions below 510 kHz or above 1705 kHz shall be attenuated at
least 20 dB below the level of the unmodulated carrier. Determination of
compliance with the 20 dB attenuation specification may be based on
measurements at the intentional radiator's antenna output terminal unless
the intentional radiator uses a permanently attached antenna, in which case
compliance shall be deomonstrated by measuring the radiated emissions.